Choose by where your data must go. Each product does that job fully, and you pay for nothing you would not switch on.

Cloud only

To your cloud: Modbus IoT Gateways

Read-only and outbound only: nothing on the internet can write to your plant.

ProductChoose this when…Connects toData leaves viaStatus
Modbus IoT Gateway Lite — 4G
CL-G-M-S/C
Brochure (PDF)
The site has no wired internet, or none you can use, and the data must reach your cloud.Up to 32 Modbus devices, RS-485 and Modbus TCP (up to 6 over TCP)4G LTE Cat 1, dual SIM — MQTT with TLS 1.2Evaluation units available
Modbus IoT Gateway Lite — Ethernet
CL-G-M-S/E
Brochure (PDF)
The site already has a network and you want no SIM or data plan.Up to 32 Modbus devices on 2 × RS-485 and Modbus TCP (up to 6 over TCP)Wired Ethernet — MQTT, outbound onlyEvaluation units available
Modbus IoT Gateway Lite — Battery 4G
CL-L-M-S/C
Brochure (PDF)
A meter far from mains power and cables must report to your cloud.Up to 4 Modbus devices on one RS-485 port, 32 values in all4G LTE Cat 1 — MQTT with TLS 1.2, a few sessions a dayEvaluation units available

SCADA or BMS only

To your control room: Protocol bridges

No cloud client and no radio in the box: a property of the product, not a setting an auditor must trust.

ProductChoose this when…Connects toData leaves viaStatus
Modbus RTU-to-TCP Bridge Lite
CL-B-M-S-2
Brochure (PDF)
Your SCADA or HMI must read RS-485 devices over the LAN, and the box must have no internet capability.Up to 32 Modbus RTU devices on 2 × RS-485None — Modbus TCP server on the LAN onlyEvaluation units available
Modbus-to-BACnet Bridge Lite
CL-B-D-S-2
Brochure (PDF)
Modbus meters, drives, chillers or gensets must appear in your building management system.Up to 32 Modbus RTU devices on 2 × RS-485, plus 5 Modbus TCP devicesNone — BACnet/IP server on the LAN onlyEvaluation units available

All in one

Both, from one box: Plus and Pro

Built on the same libraries and the same Configurator as the Lite range, so moving up does not mean starting again.

ProductChoose this when…Connects toData leaves viaStatus
Modbus-to-BACnet Bridge PlusA larger building needs more devices and points, alarms and trends in the bridge, or a BTL listing.Up to 64 Modbus RTU devices on 2 × RS-485, plus 32 Modbus TCP devicesNone in the first release — BACnet/IP on the LAN; 4G or Ethernet cloud option laterIn development
Multi-Protocol Gateway ProOne site mixes Modbus and BACnet equipment and the data must reach several systems at once.Modbus RTU and TCP, BACnet/IP and MS/TPEthernet with automatic failover to a second linkIn development

The same in every Lite product

One tool: the ConnectLinks Configurator, a Windows application over USB-C. Commissioning happens at the panel, with a cable: there is no web page to secure and no cloud account to create.Your systems, not ours: the gateways publish to your own MQTT broker and the bridges serve your own SCADA or BMS; there is no ConnectLinks cloud and no subscription.Evaluation or licensed: a unit is ordered either as an evaluation unit, a 30-day full-function trial activated later by a key for that unit, or as a licensed unit.

Sectors served

Water and utilities, solar and energy, manufacturing, commercial buildings, agriculture and irrigation, pharmaceutical and defence. The choice is set by the site's conditions (power, network, where the data must go) more than by the industry.