What it does
Built for borewells, pump houses, canals and tanks: sites with a Modbus meter and no mains supply or network cable. The gateway powers the meter only while it reads it, stores each reading with its time, quality and the battery voltage, and sends the batch to your MQTT broker over 4G.
No reading lost
Each reading is stored in 16 MB of flash before it is sent and is deleted only after your broker confirms it, even through a power cut.
Change settings without a visit
Send a change by SMS (allowed numbers and a PIN) or over MQTT. If a change cuts the unit off from your broker, it undoes itself. A health report with battery, signal and backlog arrives with every session.
Any Modbus meter, no special firmware
Set the registers and data types for your meter in the field. Readings every 1 minute to 7 days; uploads at least once a day.
Battery life